Diode lasers are the most cost effective dental lasers as their costs have come down tremendously in the past decade and the spectrum of indications are pretty wide even though tissue removal is limited to soft tissues.
There are 3 widely surgical diode lasers with different wavelengths; 810, 940 and 980nm. A 1064nm diode laser is also found in the dental market. All of these wavelengths are absorbed in melanin and haemoglobin at different levels. Absorption in melanin decreases with longer wavelengths, whereas absorption in haemoglobin icreases. That means 810nm diode is expected to work faster with pigmented tissue and 980nm is expected to be faster working in a vascularized tissue. 940 nm is placed in the middle. One important property of 980nm is that it is also absorbed higher in water compared to the other diode wavelengths, making it easier to vaporize tissue. While this creates a faster excision, it also leads to quick dehydration, which in turn may lead to carbonisation. Practitioner should be aware of the absorption differences and treat according to the optical properties of the tissue.
The other group of diodes are called low level lasers with wavelengths generally falling between 500-700nm. They are used with very low powers (<0.5W) and used for biomodulation or activation of a photosensitizers, which can be toluidine blue, methylene blue or indocyanine green. These photosensitizers attach to microorganisms and release singlet oxygen atoms which are toxic and kill the bacteria.
The biomodulation is realized through the absorption of the low levels of penetrating energy by the organelles of cells; especially mitochondria which is the power house of the cell and produces the adenosine tri-phosphate (ATP). This helps to carry out the activities in a faster or increased manner. This energy also has an analgesic and myorelaxing effect. Myorelaxation is both effective on masticatory and accessory muscles and is also vasodilatation, increasing the blood flow and lymphoid flow, promoting healing. Biomodulation may also help for nerve regeneration on case of a nerve damage, during an implant surgery, for instance.
The main difference of diode lasers than the other laser groups is that they work on a continuous wave mode, which means the flow of laser energy is naturally continuous rather than free-running pulsed because the pumping source of the semi-conductors used to create the laser light is electricity. As the first “purpose-built” laser for dentistry was Nd:YAG lasers and they were pulsed, diodes were also tried to copy them by manipulating the flow of energy by chopping it. The earlier devices had a mechanical part occluding the output of the lasers by turning wheels, while the modern devices have electric circuits turning the laser flow on and off. This is meant to let the tissue cool down, however lowering the average power also causes slowing down of the intervention which may cause accumulation of heat. The possibility of temperature rise is especially important if there is a delicate anatomical structure like mandibular nerve or salivary gland, or even bone, underlying the operation area if the temperature rise is very high. (Spencer 1998) Shrinkage after treatment may also be observed if too much heat is accumulated on the target tissue.
Another very important variable is the hand movement speed. Too fast may not be effective and too slow may cause thermal side effects.
Diodes are good tools for disinfection, both in periodontics (Fig 12) and endodontics. (Bago et al. 2012, Gutknecht et al. 2000, Moritz et al. 1997, Giannelli et al. 2012, Harris et al. 2004) The advantage of diodes in periodontal pockets being able to remove the epithelium layer selectively in addition to killing the bacteria in the pocket. Furthermore the scattered energy in the tissue is speculated to have biomodulatory effect, which helps for healing. It is also possible to disinfect the surface of the implants in a case of peri-implantitis after removing the granulation tissue by conventional methods. It is not possible to remove granulation tissue after raising an access flap with diodes since they work thermally and can damage the neighbouring bone and cause resorption. However diodes can be used for implant uncovering (El-Kholey 2013) as long as the exact location of the underlying implant is known or seen. While diodes have no harm on the implant surface, heating of the bone, especially around the neck of the implant may cause serious problems in the long run.
In endodontics, diodes can help with deeper disinfection as they are not highly absorbed by dentine and can penetrate to kill the bacteria in the dentinal tubules, lateral canals etc, however the presence of dark material like necrotic tissue, blood remnants etc. reduces the penetration and deep disinfection effect of diode lasers. 980nm diode lasers’ higher absorption in water causes the penetration to be less. Also with endodontics the scattering energy around the root may have biomodulatory effect helping to have quicker resolution of the lesions. The penetration property of diodes through hydroxyapatite helps in deep disinfection of cavity floors and extraction sockets.
Disinfection is also useful with necrotizing ulcerative gingivitis, aphtous lesions (Fig 11) and herpes lesions (Donnarumma 2010) .
Diodes are very good in vaporizing and coagulating soft tissues especially if the tissue is pigmented or vascularized. This makes them an appropriate tool to incise or excise. Indications like frenectomy, gingivectomy, overgrowth removal, operculectomy, fibroma/granuloma (Goharkhay et al. 1999, Parker 2007 A and B)
removal and many more similar interventions can be carried out with little anaesthesia and with no or very little post-op discomfort. In cases where interaction (absorption) is not taking place or penetration is required to be minimised, the tip of the fiber is carbonised to get it darkened in colour. This practice is called initiating or activating the fiber. This method actually creates a hot fiber, cutting/vaporising tissue with the heat of the tip. It is especially effective if the tissue is pale and thick.
Diodes are routinely used for crown lengthening cases, however the practitioner must remember that removing hard tissues is not possible with diodes. Leaving three centimetres for the biological width should be practiced to avoid future crown margin periodontal issues. If there is not enough soft tissue and the bone is on the way, a flap should be raised to remove and shape the bone after levelling the gingiva.
Troughing is one of the applications of diode lasers, shrinking the tissue around a prepared crown for a better impression. It is very important to assess the phenotype of the gingiva for this use of lasers because the thin gingiva may be negatively affected and show recession later on during the healing.
Haemangioma treatment is a unique non-surgical treatment for near infrared lasers. The absorption of the energy gives way to coagulation, causing no bleeding unlike surgical removal of haemangiomas. The coagulated lesion can either heal by itself in time, depending on the size, or can be removed safely without a risk of excessive bleeding.
Due to the same interaction haemostasis is also very successful with diodes. For example, coagulation may be needed on the donor site for a soft tissue graft where palatinal artery may be damaged during the collection of the graft. (Fig 13)
Hypersensitivity treatment can be carried out with diode lasers in two modes of interaction; higher levels of power may interact with dentine and narrow the dentinal tubule openings on the root surface or lower levels of power may affect the pulp and nerve ends, lowering the reactiveness. The fluoride gels are more effective when used with diode lasers
Activation of whitening gels are possible as long as they are pigmented. The pigmentation increases the absorption and temperature rise in the gel, increasing the speed of activation of the gel to bleach the teeth. (Sulieman et al. 2006) (Fig 14)
Similarly the melanin in the hyperpigmentation of the gums creates an ideal absorption interaction for depigmentation. (Fig 15)
Bago I PV, Gabric Panduric D, Schauperl Z, Baraba A, Anic I. Antimicrobial efficacy of a high-power diode laser, photo activated disinfection, conventional and sonic activated irrigation root canal treatment. Int Endod J. 2012 published online 26.07.2012.
Donnarumma G1, De Gregorio V, Fusco A, Farina E, Baroni A, Esposito V, Contaldo M, Petruzzi M, Pannone G, Serpico R. Inhibition of HSV-1 replication by laser diode-irradiation: possible mechanism of action. Int J Immunopathol Pharmacol. 2010 Oct-Dec;23(4):1167-76.
El-Kholey. Efficacy and safety of a diode laser in second-stage implant surgery: a comparative study Int J Oral Maxillofac Surg. 2013 Nov 6 [Epub ahead of print]
Giannelli M, Formigli L, Lorenzini L, Bani D Combined photoablative and photodynamic diode laser therapy as an adjunct to non-surgical periodontal treatment: a randomized split-mouth clinical trial. J. Clin. Periodontol. 2012;39(10):962-70
Goharkhay K., Moritz A., Wilder-Smith P., Schoop U., Kluger W., Jakolitsch S., Sperr W.; Effects on oral soft tissue produced by a dione laser in vitro. Lasers Surg. Med. 1999: 25(5): 401- 406.
Gutknecht N VGD, Conrads G, Apel C, Schubert C, Lampert F. Diode laser radiation and its bactericidal effect in root canal wall dentin. Journal of clincal laser medicine & surgery. 2000;18(2):57-60.
Harris DM, Yessik M (2004) Therapeutic ratio quantifies laser antisepsis: ablation of Porphyromonas gingivalis with dental lasers. Lasers in Surgery and Medicine 35(3):206-13
Moritz A GN, Schoop U, Goharkhay K, Doertbudak O, Sperr W. Irradiation of infected root canals with a diode laser in vivo: Results of microbiological examinations. Laser Surg Med. 1997;21:221-6.
Parker S. Lasers and soft tissue: 'fixed' soft tissue surgery. Br Dent J. 2007 Mar 10; 202(5): 247-253.
Parker S. Lasers and soft tissue: 'fixed' soft tissue surgery. Br Dent J. 2007 Mar 10; 202(5): 247-53
Spencer P, Cobb C M, Wieliczka D M, Glaros A G, Morris P J. Change in temperature of subjacent bone during soft tissue laser ablation. J Periodontol 1998; 69: 1278-1282.
Sulieman M, Rees JS, Addy M. Surface and pulp chamber temperature rises during tooth bleaching using a diode laser: a study in vitro. Br Dent J. 2006 Jun 10; 200(11): 631-634;
Dental Business Management Tips
Webinar

Asnsnportal.com Webinars deliver a unique web educational experience through both its live interactiove seminars and recorded seminars...