The Reevaluation of Rotary Endodontics

Dr. Barry L. Musikant

Enough new data exists today to seriously reevaluate some of the endodontic “truths” that define our understanding of this paradigm. The recognition of rotary NiTi as an effective method of instrumentation is founded on two factors that did not exist prior to its introduction. It’s increased flexibility leading to the rotation around curves with instruments of tapers greater than 02.

Having the ability to rotate around curves without inducing significant distortions is a property that stainless steel instruments do not have. They are too stiff and myriad studies have shown compared to rotary NiTi, K-files when shaped to similar apical dimensions cause greater deviations from the original anatomy. This data reinforces the notion that K-files use should be limited to creating a centered glide path for the subsequent use of rotary NiTi, a function that does not exceed preparing the canals to a 20. Most of these distortion studies are done on plastic blocks where the original canal is conical in cross-section throughout its length. Studies on extracted teeth compare the distortion as a function of the deviation in the original anatomy limited to the mesio-distal plane. Without any consideration of canal anatomy in the bucco-lingual plane, the results are designed to reinforce what is considered, a priori, rotating NiTi’s strengths, namely less potential to distort canals while achieving a fully shaped canal relatively quickly. The radiographic results of prepared canals showing smooth conical shapes filled uniformly with opaque gutta percha and cement reinforce this pleasant notion.

Intruding into this pleasing imagery, are new micro-ct studies that give the dentist the ability to view pulpal anatomy in three dimensions displaying configurations that have nothing in common with the simplistic view of the pulp as conically shaped tissue inclusions (http://rootcanalanatomy.blogspot.com.br/). Rather, we observe pulpal tissue often in the configuration of highly oval and sheath-like inclusions quite flat in the mesio-distal plane and quite wide in the bucco-lingual plane along with a variety and degree of curves and complicated branching from orifice to apex. We know that when the pulpal tissue is thin in the mesio-distal plane it reflecting the thin external anatomy of the roots in that same plane. The micro-ct studies clearly point out the detrimental effects of greater tapered instrumentation in the mesio-distal plane when such conditions exist, namely the excessive removal of coronal dentin particularly on the furcal side of roots. While the angle of deviation in the enlargement of the canal may be minimal, the greater problem is excessive removal of tooth structure where the root is the thinnest leading to an increased incidence of strip perforation and needless removal of tooth structure where it is most needed. Such excessive removal of dentin in the mesio-distal plane is accompanied by inadequate removal of pulpal tissue in the far wider bucco-lingual plane. It has been suggested that the preparation of the canals can be extended bucco-lingually by “brushing” the rotating NiTi instruments in these directions. Yet, these bucco-lingual extensions are most often quite thin and it is unlikely that greater tapered instruments can successfully negotiate these flattened spaces. The fact that greater tapered instruments cannot predictably intrude into these thin spaces is a plus in one sense. Imagine, imposing a greater tapered shape, along the bucco-lingual length that has already undermined the dentin in the mesio-distal plane due to its excessive width and now drag that type of greater tapered preparation along the entire bucco-lingual plane. It would exacerbate a locally induced centered defect to the entire bucco-lingual length of the canal.

As we appreciate the sheath-like quality of pulpal tissue inclusions it becomes increasingly obvious that the superimposition of greater tapered instruments is doing more harm than good, that the radiographic results that we see interpreted today as a step forward is in fact, undermining the strength of the roots and the small deviations in the mesio-distal plane that distortions studies say is a plus is really a misrepresentation in the overall impact of rotary NiTi shaping. If this is indeed the case, what constitutes a safer more thorough method of effective instrumentation? The key to full cleansing with minimal sacrifice of dentin in both the mesio-distal and bucco-lingual planes is to use instruments that are smaller than the canals that they are in to shape the canals. For example, an 06 vertically fluted stainless steel instrument has the body to work against all the canal walls. Its thin apical dimensions and 02 taper can gain access along a greater portion of the wide bucco-lingual extensions. Used in a 30º handpiece oscillating at 3000-4000 cycles per minute, the 06 tipped 02 tapered stainless steel vertically fluted instrument shaves a uniform layer of dentin away from all the canal walls. Limited to an arc of 30º even a thin instrument is not subject to breakage. Used vigorously against all the walls of the canal, the space thus created allows the easy introduction of the next instrument in the sequence to rapidly reach the apex. In this manner, not only is the glide path shaped to the apex, but a uniform layer of dentin is being removed along all the walls of the canal throughout the entire sequence. The result is a final shape that reflects the original canal anatomy without excessive tooth structure being removed mesio-distally and inadequate removal of tooth structure being left bucco-lingually.

Today we are all becoming increasingly aware that the imposition of large conical shapes are the wrong way to go. Yet, we must admit that the concept of creating a space that would subsequently be filled by a gutta percha point of similar dimensions was one that attracted us. Once we retain the original canal anatomy in larger form we know that a gutta percha point even having apical tugback is not fitting intimately along length. This should not be a concern because the interface between the canal wall and the gutta percha can uniformly be filled with a variety of cements that create an excellent seal along length. Certainly lateral condensation can be used to fit extra well-coated points. However, I would add that the force on a spreader creating lateral space should never exceed the weight of one’s hand. It makes no sense to apply pressure via a tapered stainless steel or NiTi spreader to a degree that increases the stresses to the root. Nor does it make sense to apply so much pressure that we deform the gutta percha point already in the canal. Gutta percha being a rubber-like material will distort under pressure, but will rebound when the pressure is removed creating a void where the cement was previously displaced under pressure. The literature is also clearly showing thermoplastic techniques all shrink rapidly and significantly under pressure creating gaps. I prefer the use of an epoxy interface that does not shrink upon polymerization while bonding to both the canal walls and the gutta percha. Being a polymer it is highly resistant to hydrolytic degradation and with the introduction of nanotechnology is capable of infiltrating deeply into the dentinal tubules.

Coming back to rotary NiTi preparations, we now see where its use violates the preservation of dentin, thins out the remaining dentin in the mesio-distal plane increasing the vulnerability to strip perforations on the furcal side of many roots. Associated with excessively thinned out roots is the increasing possibility of the production of micro-cracks in these vulnerable areas. According to the latest research, dentinal micro-cracks exist prior to instrumentation often on the external surfaces of roots. By widening excessively in the mesio-distal plane we increase the chances of the internal canal preparation communicating with these pre-existing defects, an event that can only lower the chances for successful endodontic treatment.

The key is the preservation of as much dentin as possible consistent with effective cleansing of the canal. Reducing the degree of tapered preparations is a plus. Using lesser tapered instruments with shorter arcs of motion will not only eliminate instrument separation, but according to a good deal of research will also dramatically reduce if not eliminate completely the production of dentinal micro-cracks. The logic behind this observation is strong. If short arcs of motion prevent instrument separation, it means the walls of the canals are not imposing enough stress to the instruments to lead to their breakage. In like manner, the instruments are not imposing enough stress on the canal walls to induce dentinal defects. One is the mirror-image of the other. Research studies have not explicitly stated such a correlation, but it reflects common sense.

In summarizing, where greater tapered shapes were once considered desirable, we are now becoming more aware of their downsides. Where conical shapes viewed in the mesio-distal plane were considered the mark of excellence, we now know they are associated with the excess removal of coronal dentin in the mesio-distal plane where roots are at their thinnest and in no way give us any information on the inadequacy of tissue removal in the bucco-lingual plane. We intuitively know that any technique that removes excess tooth structure and has the potential to create dentinal micro-cracks, something that logic tells us go hand-in-hand, calls for modifications that reduce both these outcomes. One alternative is the use of lesser tapered stainless steel relieved vertically fluted instruments confined to short arcs of motion that have been shown to produce no dentinal micro-cracks while having the ability to remove a more or less uniform layer of dentin from all the canal walls retaining the original highly oval anatomy of the canals in larger form.

Dental Business Management Tips

Read our exclusive dental tips for Dental Business Management
learn how to manage and communicate with your patient from our expert

 

anna-2

Dr. Anna Yiannikos

 DDS, MSc, LSO, MBA

Course Leader/Director of DBA

Enter now

Webinar

Asnsnportal.com Webinars deliver a unique web educational experience through both its live interactiove seminars and recorded seminars...